European Facility For Airborne Research

European Facility For Airborne Research Dec. 22, 2024, 03:51

Instrument: RGB Multispectral camera Duncantech MS 4100

Name RGB Multispectral camera Duncantech MS 4100
Acronym RGB Multispectral camera
Manufacturer Duncantech
Operated by CNR-ISAFoM
Operated onboard

Instrument type

Name Imaging Spectrometer
Acronym Imaging Spectrometer

Principle of operation

Measured parameter Radiance Spectra
Operating principle

Measurement(s) Hyperspectral

Dimension and weight

External dimension 0.1*0.1*0.25 m
Weight 1.8

Performance

Operating mode Remote sensing
Range

Resolution

Sensitivity

Accuracy

Bandwidth

Modifications

Operational restriction

Operational requirements

Operating Voltage 12 VDC
Power Consumption 15 Watts

Certification approvals

Additional information

- Image output: Digital Image OutputCameraLink, EIA-644 (LVDS) or RS-422: 8 bits x 4 taps or 10 bits x 3 taps,

- Signal/Noise 60 dB
- Lens Mount Nikon Bayonet Mount
-Gain SelectionRange: 0-36 dB. Controlled via RS
- External Trigger Input Edge or level, three modes External Trigger Source BNC or Frame Grabber (Optical isolator on BNC)
- Exposure Control: Manual or Automatic
- White Balance: Manual or Semi
- Noise Reduction: Correlated Double Sampling
- Usability Features: Digital cross hairs, Color
- Operating Temperature 0-50 C
- Programmable Functions: Gain, exposure time, multiplexing, trigger, modes, custom processing
- DirectView Output: Progressive Scan RGB (1280x1024 max display resolution). Gamma correction.
2x and 4x digital zoom

Access, host and processing

Access

may be rented

Could also fit on any aircraft having the following characteristics

General description

Title Author Type Related
No documents.
Back to top
Copyright © 2024 EUFAR All rights reserved.